Diagnostics

Adulteration Calibrators and COntrols

Sciteck® Diagnostics Extensive Line of Adulteration Calibrators and Controls meet and / or exceeds every CAP FDT (The Gold Standard), SAMHSA (HHS) and CLIA Guideline requirements and cutoffs.

Products Lines:
SVT® Specimen Validity Testing Controls 1, 2 and 3
SAM-SET™ Calibrators and Controls Series
UR-N-TROL™ Adulteration Controls
AdultaCheck® Quality Controls Series

Custom Calibrators and Controls: Just contact us if you are interested in having a custom calibrator or control manufactured for your specific needs.

Drug testing random image

AYP0621908.jpg

Sciteck® Diagnostics line of Calibrators and Controls are for use in Adulteration (specimen validity testing) for pH, Creatinine, Nitrite, Chromate, Oxidants, Aldehydes, Peroxidase, Enzymes (amylase) and Halogens (to include Bleach). These Calibrators meet or exceeds every regulatory agencies (CAP FDT the Gold Standard, SAMHSA and HHS CLIA accredited laboratories) guidelines for adulteration testing on human saliva and urine for use on automated clinical chemistry analyzers or adulteration test strips (e.g. AdultaCheck®). The Calibrator and Controls are not for use in diagnosing disease or illness to effect treatment, and/or cure. They are for Forensic / Toxicology use only. The Calibrators and Controls are ready to use liquid controls for use on autoanalyzers or dry chemistry methods. They are sold individually or in sets and may be used with any reagent lot.

Auto-UA-Bottles-Instrument-photoglassware colored beakers and flaskAdultaCheck boxesglassware balance colored flaskAdultaCheck QC bottles

SVT™ Adulteration Controls Insert
SVT™ Product Numbers and Ordering Information

Sciteck Product Catalog


SVT™ Quality Control Series

Usage: SVT™ Controls are for use in validity tests for pH, Creatinine, Nitrite, and Oxidants as required in the proposed SAMHSA guidelines in human urine on automated clinical chemistry analyzers. The SVT™ Control Series are not for use in diagnosing disease or illness to effect treatment, and/or cure. They are for Forensic / Toxicology use only. The SVT™ Controls are ready to use liquid controls for use on autoanlyzers or dry chemistry methods. SVT™ Controls are sold individually or in sets and may be used with any reagent lot.
Storage and Stability: Store at 2-10° C. The reagent is stable until expiration date on the container.

Catalog # A4300
SVT™ Level 1 (60 mL)
Assay / Target Levels / Range
pH / 2.50 / 2.1 - 2.9
Oxidant (Nitrite) / 0.0 mcg/mL
Nitrite / 0.0 mcg/mL
Creatinine / 23.0 mg/dL / 21-25 mg/dL

Cataqlog # A4400
SVT™ Level II (60 mL)

Assay / Target Levels / Range
pH / 7.0 / 6.0 - 8.0
Oxidant (Nitrite) / 350 mcg/mL / 200 - 500 mcg/mL
Nitrite / 350 mcg/mL / 200 - 500 mcg/mL
Creatinine / 12.5 mg/dL / 5.0 - 20.0 mg/dL

Catalog # A4200
SVT™ III Control (60 mL)
Assay / Target Levels / Range
pH / 10.5 / 9.0 - 12.0
Oxidant (Nitrite) / 565 mcg/mL / 500 - 625 mcg/mL
Nitrite / 565 mcg/mL / 500 - 625 mcg/mL
Creatinine / 3.0 mg/dL / 2.0 - 4.0 mg/dL

For Additional information about the SVT® series or our Custom Reagents, Calibrators and Controls please contact us at: info@sciteck.org

Ordering information:
Phone: 828-650-0407 / 800-749-4537
Fax: 828-650-2735
e-mail: info@sciteck.org